Copper-coated solid wire designed for welding carbon and carbon-manganese steels with tensile strength up to 510 MPa. Suitable for single pass or multi-pass welding. Applications include tanks, boilers, steel structural works, earthworks and construction works. To be used under the shield of Ar+CO2 or CO2.
C | 0.07 |
Si | 0.60 |
Mn | 1.20 |
C1 | M21 | |||
Yield strength | 400 MPa | 420 MPa | ||
Tensile strength | 480 MPa | 530 MPa | ||
Elongation | 26 % | 28 % | ||
Impact test Kv (-20°C) | 50 J | 70 J |
Diameter (mm) | Volts | Ampere |
0.6 | 15-26 | 50-180 |
0.8 | 16-28 | 60-200 |
1.0 | 17-32 | 80-260 |
1.2 | 18-34 | 100-360 |